Technical Features Professional Design
Safety Configuration
Professional software
Technical Specifications
Test Principle Installation of catheter clamps in the clamping slots of the clamping system. Adjust the spacing between the two sliding clamps to the specified clamp spacing and then tighten the clamping tabs, ensure that the catheter clamps maintain a good fit. The end of the test catheter is passed from bottom to top through the two catheter clamping tabs, and the upper clamp of the tester holds the head of the catheter. Insert the rest of the catheter into the drum filled with water, hang naturally and soak for the manufacturer's recommended time. Adjust the position of the two sliding clamping blocks in the slots, let the catheter in the central position. Start the tester so that the catheter passes through the silicone sheet a sufficient distance, record force versus displacement curves. Take the average force value of the wetted section of the catheter body on the curve to report the results. Standards T-CAMDI 021-2019 Single-use hydrophilic coated guidewire YY/T 1536-2017 Catheters other than intravascular catheters-Standard test model for evaluating the surface sliding performance Applications Non-vascular catheters such as urinary catheters, drainage tubes, endotracheal tubes, balloon catheters etc., intravascular catheters, guidewire Configuration Standard Configuration: Instrument, Computer, Water bath temperature control device, Automatic clamping device, Silicone Catheter pads, Specialized fixtures, Professional software and communication cable. Optional Parts: Non-standard fixture (customized) Automatic clamping force device |
|||||||||||||||||||||||||||
Specifications | PSPT-03 |
Load Cell Capacity | 10N (standard); 5N,30N, 50N (optional) |
Testing Accuracy | 0.5% FS |
Testing Speed | 0.05~1000 mm/min (Adjustable) |
Accuracy of Speed | ±1% |
Maximum Stroke | 500mm |
Number of Friction | 1~999 |
Number of Specimens | 1 |
Test Distance of Catheter | >150mm |
Clamping Way | Manual |
Power Supply | AC 220V 50Hz/120V 60Hz |
Instrument Dimension | 340mm(L)×450mm(W)×1310mm(H) |